Who the 2022 fire door rules apply to
The Fire Safety (England) Regulations 2022 have been in force since 23 January 2023, and they apply in England only. They sit under the Fire Safety Order 2005, which puts fire safety duties on the responsible person. In a block of flats that's usually the freeholder, a residents' management company or the managing agent acting for them.
The fire door duties attach to buildings with two or more sets of domestic premises and common parts that residents would use to get out. In plain terms, a block of flats or a house converted into flats with a shared hall and stairs. A single family house isn't covered. Neither is your own front door if you live in a house.
Since 16 May 2022 the Fire Safety Act 2021 has also made it clear that the Fire Safety Order covers every door between a flat and the common parts. So the flat front door is part of the building's fire safety, even when the leaseholder owns it.
If you let a shared house rather than self-contained flats, whether these duties apply depends on how the building is laid out. The fire door standard in a licensed shared house usually comes from the council's licence conditions and the fire risk assessment, so ask your council's private housing team.
What does Regulation 10 actually require?
Two things. Every block with two or more flats must give residents fire door information when they move in and at least once a year. Blocks whose top storey is more than 11 metres up must also have their communal fire doors checked every three months, and the flat front doors checked every year on a best endeavours basis.
| Rule | What it means for you | Source |
|---|---|---|
| Any block with two or more flats and common parts: residents must be told to keep fire doors shut when not in use, not to tamper with self-closers, and to report faults or damage straight away. | New residents get this as soon as reasonably practicable after moving in, and everyone gets it again at least every 12 months. | Fire Safety (England) Regulations 2022, regulation 10 |
| Top storey more than 11 metres above ground: fire doors in the common parts must be checked at least every three months, including their self-closers. | Stair doors, lobby and corridor doors, and doors to risers, cupboards and plant rooms. Lift landing doors aren't included. | GOV.UK fact sheet: fire doors (regulation 10) |
| Top storey more than 11 metres above ground: the responsible person must use best endeavours to check every flat entrance door at least every 12 months. | Best endeavours means asking for access and keeping a record of each attempt, including the flats where access wasn't given. | Fire Safety (England) Regulations 2022, regulation 10 |
| Blocks under 11 metres have no set check intervals, but they aren't free of duties. | Residents still get the fire door information, and the general fire safety duty still means fire doors, flat front doors included, have to do their job. | GOV.UK fact sheet: fire doors (regulation 10) |
| The regulations don't require existing flat entrance doors to meet the standard for a new block. | A door that met the standard when it was made or fitted will usually still be adequate if it's undamaged and the gaps aren't too big. | Home Office fire door guidance, revised August 2025 |
Who signs it off
- The responsible person: the checks, the records and the resident information
- Residents: keep doors shut, leave the closers alone and report damage
- A competent contractor: the repairs and replacements a check turns up
- The fire risk assessor: anything that needs more than a visual check
Checked November 2026 against the Fire Safety (England) Regulations 2022, the GOV.UK regulation 10 fact sheet and the Home Office fire door guidance
What a fire door check looks at
The Home Office guidance describes the checks as simple and visual. A caretaker or managing agent can do them with some instruction, and no tools are needed. These are the points it lists.
- The gap between door and frame. The industry standard is never more than 4mm, and gap tester cards make it quick to check.
- The gap under the door: as small as practicable without the door catching if it drops a little on its hinges.
- Closing: open the door fully and let go, then open it to about 15 degrees and let go. Both times it should close fully into the frame.
- Intumescent strips and smoke seals: undamaged, in contact with the door or frame, and not painted over.
- Hinges and ironmongery: no missing or loose screws, and no damaged grilles or fittings.
- Glazing: fire-resisting glass in the door and any side or top panels, with no cracks or broken panes.
- Letterboxes that close properly and aren't jammed open.
- Damage or alterations: warping, a split in a timber door, or a hole where an old lock was taken out.
- A self-closer on every flat front door and communal fire door, and one that actually works.
What makes a door a fire door
A fire door is a doorset, not a slab of wood. The leaf, the frame, the intumescent strips and smoke seals, the hinges, the closer, the lock and any glass were tested together, and the rating only holds if they're fitted together the way they were tested. Change one part for something that wasn't in the test and you've got a door that looks right and may not be.
Ratings are written two ways. FD30 is the British rating for 30 minutes of fire resistance, and an S on the end means it also limits smoke leakage. The European classification for the same job is written E 30, with Sa for smoke. Approved Document B uses both for now.
A few rules in Approved Document B are worth knowing. Hinges that weren't tested as part of the doorset must have their essential parts made from materials that melt at no less than 800°C. Recommendations for fitting and maintaining timber fire doors are in BS 8214. And the gaps, the hinge positions and how much can be trimmed off the door come from the maker's data sheet and test evidence, not from a general rule.
That last point catches people out. A fire door trimmed past its data sheet limits isn't a fire door any more, whatever the label on the edge says. If the opening is badly out, the opening gets sorted, not the door.
Which doors in a block or a house need to be fire doors?
The usual answer from Approved Document B Volume 1 for flats and houses. The building's fire strategy or fire risk assessment has the final say on any particular door.
| Where the door is | Minimum rating | Self-closer? |
|---|---|---|
| Flat front door onto a shared corridor or stair | E 30 Sa (FD 30S) | Yes |
| Doors enclosing a shared protected stair | E 30 Sa (FD 30S) | Yes |
| Lobby or corridor doors on the way to a shared stair | E 30 Sa (FD 30S) | Yes |
| Doors off a protected entrance hall inside a flat | E 20 (FD 20) | No |
| Between a house and an integral garage | E 30 Sa (FD 30S) | Yes |
| Onto the protected stair in a house with a floor more than 4.5m up | E 20 (FD 20) | No |
From Approved Document B Volume 1, Table C1 and paragraph C5. Fire doors inside flats and houses don't need self-closers, except the door to an integral garage.
Flat front doors: repair, replace or leave alone?
This is where we see the most money wasted. The Home Office guidance is clear that the regulations don't require existing flat entrance doors to meet today's standard for a new block. It goes further: missing intumescent strips, smoke seals or certification don't on their own mean a door is unfit, and the government says it's concerned about leaseholders being wrongly told to replace doors that are fine.
So if a check flags a door, start by asking what's actually wrong with it. A loose hinge, a closer that's been unhooked, a gap that's opened up at the head or a seal that's been painted over can usually be put right. A door with a split leaf, a hole from an old lock or a gap that can't be closed up probably can't.
If a door does need replacing, the guidance says the new one should be fire-resisting, fitted by a competent person, and come with its technical information for the responsible person. Any change to a flat front door should be agreed with the responsible person first. In practice that means the freeholder or managing agent seeing the specification before the old door comes off.
Our view: repair where the door is sound, replace where it isn't, and keep the paperwork either way.
Where fire door fitting goes wrong, and what we do instead
Fire doors usually fail through small things done on the day they were fitted, or a year later by someone who didn't know what they were looking at.
- The shortcut
Leaf planed down to fit an opening that's out of square
What we do insteadTrimmed only within the data sheet limits, with the frame or opening sorted if it needs more
- The shortcut
Any hinges from the van, two of them, on short screws
What we do insteadThe hinges, number and screw length the data sheet names, each recessed flush
- The shortcut
Gaps left at whatever the door ended up with
What we do insteadGaps set to the data sheet and checked down both sides and across the head
- The shortcut
Strips and seals painted over during decoration
What we do insteadSeals masked or fitted after painting, and left free to swell
- The shortcut
A closer that slams, so residents unhook it
What we do insteadThe closer adjusted so the door shuts and latches without slamming
- The shortcut
A spyhole, letterbox or new lock cut in on site
What we do insteadOnly fire-rated parts the doorset maker allows, fitted to their instructions
- The shortcut
The gap between frame and wall packed with offcuts and filled with ordinary foam
What we do insteadFrame fixed and the gap sealed with the fire-rated product the data sheet specifies
Fire doors in houses, and what changes in 2029
Most two-storey houses don't need fire doors at all. The exceptions are the door between the house and an integral garage, and the doors onto the stairs once a house has a floor more than 4.5 metres above the ground, which a loft conversion usually creates. If that's your situation, our loft conversions and garage conversions pages cover where the fire doors go, and Building Control has the final say on new work.
The bigger change is coming in Approved Document B itself. On 2 September 2029 the guidance drops the British FD ratings and refers only to European classifications, so FD30 becomes E 30 in every new specification. Work already notified before that date can stay on the old guidance if it's started and sufficiently progressed within six months.
Nothing about this makes an existing FD30 door wrong. What it changes is buying. If you're specifying doors for a refurbishment that might run into late 2029, ask the supplier for the European classification and the test evidence behind it now.
What this means if you manage a block or own a flat
If you're the responsible person, the checks are yours to arrange and they can be done in-house. When a check turns something up, that's where we come in. We hang fire doors to the maker's data sheet, adjust or replace closers, and tell you plainly whether a door can be repaired before anyone orders a new one. Whoever fits a new fire door, ask for its data sheet. It's the evidence the responsible person needs on file.
Fire doors have been part of our work since at least November 2021, when we posted five fire doors going in alongside skirting and a kitchen. Send us a photo of each door, the label or plug on its hinge edge if there is one, and the frame, and we'll tell you what we'd do. Our door fitting page has the detail on how we hang doors, and builders and managing agents can see how we work for them on our trade page.
If a check finds a door that won't close, a damaged leaf or a missing seal, it shouldn't wait for the next round of works. Our urgent fire door repairs page explains what we can put right quickly and what needs a new doorset.
Read next
How to check a builder before you hire themCheck five things before you say yes: the business is real and traceable, its reviews lead back somewhere, you can see its own work, it puts...
Planning permission or building regulations: which do you need?They're two separate approvals that answer different questions.
How we quote, and what sets the numberWe don't publish prices, because the same job description can hide very different work.
Sources
- legislation.gov.uk: The Fire Safety (England) Regulations 2022, regulation 10
- GOV.UK: Fire Safety (England) Regulations 2022, fact sheet on fire doors (regulation 10)
- GOV.UK: Fire Safety (England) Regulations 2022, fire door guidance (Home Office, revised August 2025)
- legislation.gov.uk: Fire Safety Act 2021, section 1
- legislation.gov.uk: The Regulatory Reform (Fire Safety) Order 2005
- GOV.UK: Approved Document B (fire safety), Volume 1: Dwellings, 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments
- GOV.UK: 2029 amendments to Approved Document B